Dental 14L Autoclave Steam Sterilizer Medical Sterilization Lab Equipment TR250E

Category Business & Industrial Healthcare, Lab & Dental Medical & Lab Equipment, Devices Autoclaves & Sterilizers

Current price $349.99

Listing type Chinese

Location CA US

Quantity sold 0

Quantity available 1

Bids 0

Seller dr.baistra (10906)

Seller rating 99.7% positive feedback

Safety Valve automatic discharge in excess of standard value

Disinfection Principle Uses the vapor power emissions cold air / 2 times

Chamber Capacity Ø25×D28CM (Ø9.84×D11.02inch)

Inside Capacity 14 Liter

Material Stainless steel #304

Country/Region Of Manufacture China

Outside Size 46.5*35*36 CM

Packing Size 51*39*40 CM

G.W 15KGS

Sterilizer Temperature 121℃

Sterilize Pressure 0.12Mpa

Sterilize Time 25Min

Brand Unbranded

Power 900W

Temp And Press Display Pressure gauge

Auto Supply Water System Manual give the water

Model TR250E

California Prop 65 Warning Stainless Steel #304

Intended Use/Discipline Biological Laboratory, Anesthesiology, Dentistry, Cosmetology, Cardiology, Dental Laboratory

Modified Item No

Sterilizer Type Autoclave (Steam Sterilizer)

MPN MJQ1020100911

UPC 0635648363639

See it on eBay →

SHIP FROM USA TO USA, SHIP FROM CHINA TO OTHER COUNTRIES!
FDA Statement:
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.
Description:
Chamber
Inside capacity:14 Liter
Material:Stainless steel #304
Outside Size :46.5*35*36 CM
Packing Size :51*39*40 CM
G.W:15KGS
Sterilizer temperature:121℃
Sterilize pressure:0.12Mpa
Sterilize time:25Min
Power:900W
AC110V/8A
AC220V/4A
Auto supply water system: Manual give the water
Safety valve: automatic discharge in excess of standard value
Temp and Press display:Pressure gauge
Disinfection principle:Uses the vapor power emissions cold air / 2 times
Operation Steps:
1. Plug in the power cord
2. Shut exhaust needle valve in the Close (clockwise)°
3. Adding about 800 ml of distilled water. Close the door cover, tight the rotate handle
4. Start the timer knob to 121 ℃ position. Sterilization is working.
5. Sterilization is complete, please be sure to open the exhaust needle valve firstly (inverse clock direction)
6. Wait for the pressure gauge pointer to zero, opened the door cover
Caution:
Every time sterilization, must add about 800 ml of distilled water
Use a separate socket (confirm the socket of the output voltage)
Pressure gauge pointer in the red areas, please be sure to first Open the exhaust steam of the needle valve
Packing:
main unit 1pc
Standard accessories:
Plate 3pcs ( Size:201*136*21 mm)
Shelf 1pc
Take Plate tool 1pc steam exhaust pipe 1pc(1 meter length)

Also popular in the category Business & Industrial → Healthcare, Lab & Dental → Medical & Lab Equipment, Devices → Autoclaves & Sterilizers